Filter Results By:

Products

Applications

Manufacturers

Current Transformers

transfers accurately proportional levels of current to multiple circuits.


Showing results: 136 - 150 of 340 items found.

  • High Current Calibrator

    MC151 - Powertek LLC

    MC151 Current calibrator is an accurate current source capable of 120 A. Typical uses include calibration of current sensors, current probes, current transformers, shunts, ammeters, DMMs or as stable current source for test and development applications. The calibrator is equipped with a built-in multimeter that can be used for simulation of programmable transconductance or current amplifier.

  • Transformer Tester

    Kvtester Electronics Technology Co.,Ltd

    High precision instrument for measuring characteristic parameters of transformer capacity, no-load and load. The instrument is a multi-function measuring instrument, which is equivalent to the usual two kinds of test instruments: the transformer capacity tester + transformer characteristic parameter tester. The utility model can precisely measure a series of power frequency parameters of a plurality of transformers, such as the capacity, the type, the no-load current, the no-load loss, the short circuit (load) loss and the impedance voltage.

  • AC / DC Current Probe, 10 MHz, 150 Arms

    N2781B - Keysight Technologies

    The N2781B current probe is an accurate and reliable solution for measuring AC and DC currents. Using a hybrid technology that includes a Hall effect sensor and an AC current transformer, the probe provides accurate measurement of DC or AC currents up to 150 Arms continuous

  • AC / DC Current Probe, 2 MHz, 500 Arms

    N2780B - Keysight Technologies

    The N2780B current probe is an accurate and reliable solution for measuring AC and DC currents. Using a hybrid technology that includes a Hall effect sensor and an AC current transformer, the probe provides accurate measurement of DC or AC currents up to 500 Arms continuous.

  • N2782B AC / DC Current Probe, 50 MHz, 30 Arms

    N2782B - Keysight Technologies

    The N2782B current probe is an accurate and reliable solution for measuring AC and DC currents. Using a hybrid technology that includes a Hall effect sensor and an AC current transformer, the probe provides accurate measurement of DC or AC currents up to 30 Arms continuous.

  • AC / DC Current Probe, 100 MHz, 30 Arms

    N2783B - Keysight Technologies

    The N2783B current probe is an accurate and reliable solution for measuring AC and DC currents. Using a hybrid technology that includes a Hall effect sensor and an AC current transformer, the probe provides accurate measurement of DC or AC currents up to 30 Arms continuous.

  • Surge Arrester Testing

    SCAR 10 - Altanova Group

    This MOV- Metal Oxide Varistor test system is the perfect device to perform analysis and diagnostics on metal oxide arrestors. It is supplied with a special current clip-on transformer designed for the measurement of current leakage.

  • Three-Phase Transformer Demagnetizer

    DEM60C - IBEKO Power AB

    After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.

  • Filament Transformers

    Osborne Transformer Corp.

    Osborne designs and produces high impedance and unregulated Filament Transformers. An unregulated filament transformer supplies a specified voltage and current to the filament of an electron vacuum tube. High impedance filament transformers are designed around a tungsten tube filament. Osborne often works with our clients to increase the life-span of their vacuum tubes through the use of a regulated voltage supply.

  • Current Probes

    Teledyne LeCroy

    Teledyne LeCroy current probes do not require the breaking of a circuit or the insertion of a shunt to make accurate and reliable current measurements. Based on a combination of Hall effect and transformer technology, Teledyne LeCroy current probes are ideal for making accurate AC, DC, and impulse current measurements.

  • Reactor Loss Measurement Systems

    Measurements International Ltd.

    The Shunt Reactor Loss Measurement System is a microprocessor controlled, metrology based, high voltage Capacitance, Inductance and Reactor Loss Measurement bridge which is based on the two stage- compensated current transformer. The 7010C bridge can be ordered by itself or it can be ordered with high voltage capacitors up to 800 kV line to ground and two-stage-compensated current transformers up to 4000A. the system is fully automatic displaying the rms voltage at the top of the capacitor, the reactor current and the reactor losses.

  • Switching Power Supplies

    PeakTech Prüf- und Messtechnik GmbH

    A type of power supply that works by switching current into a high-frequency transformer or inductor at frequencies much higher than the input or line frequency

  • Instrument Transformer Test Systems

    ZERA GmbH

    Our systems for testing voltage (VT) and current (CT) instrument transformers are conceived among other things for testing accuracy and insulation.

  • Power Quality Testing

    Weshine Electric Manufacturing Co., Ltd

    Transformer K Factor, Power factors(PF)and displacement factors, Short-term voltage flicker, .Three phase unbalance (Current and Voltage), Waveform real-time display(4 channels voltage /4 channels current) True RMS values of voltages and currents

  • Transformer Ratio Meters

    Handheld Turns Ratio & Winding Resistance Tester TWR-H - Amperis sl

    TWR-H is a handheld, battery operated, fully automatic test set specially designed for turns ratio, phase shift, excitation current and winding resistance measurements of transformers. It can also perform demagnetization of these transformers. Transformer turns ratio is determined by applying AC voltage across high voltage winding, accurately measuring AC voltage across the corresponding unloaded transformer winding, and then displaying the ratio of these voltages. User can enter a transformer’s nameplate voltages, so that turns ratio deviation can be calculated. This feature eliminates any error otherwise caused by an operator’s manual calculation. TWR-H compares measured turns ratio with the nameplate ratio and prints out the % of error for each test. Transformer winding resistance is determined by injecting DC current through a winding, accurately measuring DC voltage across the winding, and then calculating resistance as the ratio of voltage and current. The device generates true DC ripple-free currents. Both the injection of the current and the discharge of energy from transformer magnetic circuit are automatically regulated.

Get Help